GAQM CDCS-001 Exam

Certification Provider: GAQM
Exam Name: Certified Data Centre Specialist
Duration: 60 Minutes
Number of questions in our database: 40
Exam Version: Mar. 20, 2024
CDCS-001 Exam Official Topics:
  • Topic 1: Overall Considerations for Physical Security/ Physical Security Identification Methods and Devices
  • Topic 2: Power Distribution Components/ Circuit Breakers and Outlets
  • Topic 3: Cooling Layouts for Data Center/ Air Cooled Self-Contained Systems
  • Topic 4: Risk Tolerance versus Cost/ Other Physical Security Methods
  • Topic 5: Switchgear and Distribution/ Data Center Heat Removal Approaches
  • Topic 6: Internal Combustion Engine/ Identifying Main Components
  • Topic 7: Physical security measures/ Power System Failures/ Air Distribution System
Disscuss GAQM CDCS-001 Topics, Questions or Ask Anything Related

Currently there are no comments in this discussion, be the first to comment!

Free GAQM CDCS-001 Exam Actual Questions

The questions for CDCS-001 were last updated On Mar. 20, 2024

Question #1

Which component is designed to protect electrical equipment from damage caused by overload or short circuit?

Reveal Solution Hide Solution
Correct Answer: D

A circuit breaker is a device designed to protect electrical equipment from damage caused by overload or short circuit. Circuit breakers are designed to detect when too much current is flowing through a circuit and to shut the circuit off when that happens. This protects the equipment from damage due to overloading or short circuiting, and it also helps prevent fires and other accidents.


Question #2

True or False: A grounded wire is connected to metal appliance cases

Reveal Solution Hide Solution
Correct Answer: A

A grounded wire is connected to metal appliance cases in order to provide a safe path for electricity to flow in the event of a short circuit or other electrical problem. This helps to protect the appliance and the people using it from potential electrical shocks, and it also helps prevent fires and other accidents.


Question #3

Which one of the following measures the real power drawn by the load equipment?

Reveal Solution Hide Solution
Correct Answer: A

Watts measures the real power drawn by the load equipment and is determined by multiplying the volts and amps of the load


Question #4

What is a Data Center?

Reveal Solution Hide Solution
Correct Answer: C

A building or a portion of a building whose primary function is to house a computer room and its related support areas. A Data Center is a secure, temperature-controlled environment that houses computer systems, equipment, and associated components. It is typically used to store, process, and distribute large amounts of data and information. Data Centers typically include server racks, storage arrays, network switches, firewalls, and other components necessary for the operation of computer systems.


Question #5

Data Center Precision Cooling Systems maintain temperature within _____________ degree(s) of their design set point.

Reveal Solution Hide Solution
Correct Answer: A