Deal of The Day! Hurry Up, Grab the Special Discount - Save 25% - Ends In 00:00:00 Coupon code: SAVE25
Welcome to Pass4Success

- Free Preparation Discussions

VMware 3V0-23.25 Exam Questions

Exam Name: VMware Advanced VMware Cloud Foundation 9.0 Storage Exam
Exam Code: 3V0-23.25
Related Certification(s):
  • VMware Certified Advanced Professional VCAP Certifications
  • VMware VCAP VMware Cloud Foundation Storage Certifications
Certification Provider: VMware
Actual Exam Duration: 60 Minutes
Number of 3V0-23.25 practice questions in our database: 77 (updated: Sep. 17, 2026)
Expected 3V0-23.25 Exam Topics, as suggested by VMware :
  • Topic 1: IT Architectures, Technologies, Standards: Covers understanding storage architecture types (HCI vs Traditional) and their use cases, along with differentiating supported storage protocols such as iSCSI, vSAN, NFS, FC, and NVMe.
  • Topic 2: VMware Cloud Foundation (VCF) Products and Solutions: Covers vSAN OSA vs ESA differences, vSAN architecture components, Principal vs Supplemental storage in VCF Workload Domains, advanced vSAN features, storage solution components like datastores/datastore clusters, and the role of storage in a Supervisor context.
  • Topic 3: Plan and Design the VMware Solution: Covers designing and sizing vSAN storage solutions for VCF, as well as designing supported non-vSAN storage solutions based on given requirements.
  • Topic 4: Install, Configure, Administrate the VMware Solution: Covers deploying and configuring vSAN clusters (standard, stretched, 2-node), vSAN Data Protection, encryption, File Service, iSCSI Target Service, non-vSAN datastores/datastore clusters, storage policies, recovery plans, and related Day 2 administration tasks.
  • Topic 5: Troubleshoot and Optimize the VMware Solution: Covers monitoring vSAN and non-vSAN storage using VCF tools, along with troubleshooting and resolving issues in both vSAN and supported non-vSAN storage environments.
Disscuss VMware 3V0-23.25 Topics, Questions or Ask Anything Related
0/2000 characters

Currently there are no comments in this discussion, be the first to comment!

Free VMware 3V0-23.25 Exam Actual Questions

Note: Premium Questions for 3V0-23.25 were last updated On Sep. 17, 2026 (see below)

Question #1

A cache drive failed on one of the vSAN OSA nodes in the cluster.

When the drive failed, vSAN started a resync to ensure the health of the data, and all objects are showing a healthy and compliant state.

The vSAN administrator needs to replace the failed cache drive.

Which set of steps should the vSAN administrator take?

Reveal Solution Hide Solution
Correct Answer: C

In vSAN Original Storage Architecture, a disk group consists of one flash cache device and one or more capacity devices. The cache device is a required component of the disk group, so a failed cache device cannot be replaced as an isolated drive while preserving the same disk group. The supported operational approach is to remove the affected disk group, physically replace the failed cache device, verify that ESX detects the new device, and then manually recreate the disk group using the replacement cache device and the appropriate capacity devices. The scenario states that vSAN has already completed resynchronization and that all objects are healthy and compliant, so removing the failed disk group no longer risks object noncompliance. Selecting Full Data Migration on a failed cache device is not the correct workflow because the cache failure affects the entire disk group. Simply inserting a replacement drive does not cause vSAN OSA to automatically rebuild the disk group. Reference topics: vSAN OSA Disk Groups, Replace a Cache Device, Remove Disk Group, Recreate Disk Group.


Question #2

A vSAN ESA solution is configured using the following requirements:

* Seven ESX Hosts, each host contains:

32 CPU

256 GB memory

25 GbE network

12 storage devices 4 TB each

One storage pool using the 12 storage devices

* RAID-6 with FTT=2

If a storage device on a single host fails, what percentage of that host's capacity is impacted?

Reveal Solution Hide Solution
Correct Answer: C

In vSAN ESA, each host uses a storage pool instead of the older OSA disk-group model. The question asks what percentage of that host's local capacity is impacted by the failure of one storage device. Each host has 12 equal-capacity storage devices, and all 12 devices participate in one storage pool. Therefore, one failed device represents one-twelfth of that host's local pool capacity. One divided by twelve equals approximately 8.3%. RAID-6 with FTT=2 determines object resilience across hosts and fault domains, but it does not change the simple local-capacity fraction represented by a single failed disk on one host. With sufficient cluster resources and policy compliance, vSAN ESA can continue serving data and begin repair or reprotection using remaining capacity. However, the impacted local host capacity is still the failed device's share of the host storage pool. The correct percentage is therefore 8.3%, not 25%, 50%, or 0%. Reference topics: vSAN ESA Storage Pools, Storage Device Failure, RAID-6 FTT=2, Capacity Impact Calculation.


Question #3

An administrator is tasked designing a vSAN storage solution while respecting the following requirements:

* Must use vSAN ESA

* Must be stretched between two data centers

* Must configure Failures to tolerate = 1

* Must configure Erasure Coding

How many components per Virtual Machine (VM) will be created?

Reveal Solution Hide Solution
Correct Answer: B

With vSAN ESA and Failures to tolerate set to 1 using RAID-5/6 Erasure Coding, vSAN creates an optimized RAID-5 format based on the number of available fault domains. The documentation states that if five or fewer fault domains are available, ESA lists three components for RAID-5. This corresponds to a 2+1 erasure-coded layout, where two data components and one parity component are created. The stretched-cluster setting affects the site disaster tolerance rule, while the stated Failures to tolerate rule with erasure coding defines the local object protection method. The policy note also states that in a vSAN stretched cluster, the RAID-5/6 erasure coding failure tolerance method applies to the Site disaster tolerance setting. Given the answer choices, the ESA optimized RAID-5 component layout that matches FTT=1 erasure coding is three components. One or two components would not provide erasure-coded protection, and four components represents a generic RAID-5 fault-domain requirement rather than the ESA optimized component count shown in placement details. Reference topics: vSAN ESA RAID-5, Failures to Tolerate, Erasure Coding, Stretched Cluster Storage Policy.


Question #4

An administrator is presented with the following scenario:

* 20 TB of additional storage is being requested by a VM application owner.

* The application has high CPU/Memory requirements that can only be satisfied by the current cluster the application runs in.

* The application has high IOPS and bandwidth requirements to run properly.

* The existing vSAN cluster only has 10 TB of unused capacity.

* The hosts in the cluster have no additional NVMe slots left.

* The administrator does not have permission to purchase additional hosts or re-assign hosts from other vSAN clusters.

* Other vSAN clusters exist in the environment that can satisfy the requirement.

Which vSAN feature should be used to fulfill this scenario?

Reveal Solution Hide Solution
Correct Answer: A

vSAN HCI Mesh is the correct feature because the application must continue running on the existing compute cluster, but that cluster lacks enough unused vSAN capacity and has no available NVMe slots for expansion. HCI Mesh, also known as vSAN datastore sharing, allows independent vSAN clusters to share remote datastore capacity with other compatible vSAN clusters. The remote datastore can be mounted and used as if it were local storage, allowing VMs running on the current cluster to consume storage from another vSAN cluster that has sufficient capacity and performance. This satisfies the requirement without purchasing hosts, reassigning hosts, or moving the application away from the cluster that provides the required CPU and memory. vSAN Data Protection addresses snapshots and recovery, not capacity expansion. vSAN File Services provides SMB/NFS file shares, not additional VM datastore capacity. vSAN Stretched Clusters provide availability-zone resilience, not cross-cluster capacity borrowing. VCF documentation describes HCI Mesh as cross-cluster capacity sharing that enables multiple independent vSAN HCI clusters to consume storage from adjacent vSAN storage resources. Reference topics: vSAN HCI Mesh, vSAN Datastore Sharing, Cross-Cluster Capacity Sharing, Remote vSAN Datastore.


Question #5

A multinational corporation is deploying a VMware Cloud Foundation (VCF) Workload Domain cluster to host tier-1 business applications with the following requirements:

* Deliver high performance to all workloads.

* Integration with automated VM placement.

* Reuse of existing infrastructure including multiple Fibre Channel (FC) arrays partitioned by business unit.

* The storage architecture must avoid vSAN.

* Meet organizational separation requirements.

Which two deployment approaches meet these requirements? (Choose two.)

Reveal Solution Hide Solution
Correct Answer: A, B

Dedicated VMFS datastores on assigned Fibre Channel arrays meet both the performance and separation requirements. VCF supports Fibre Channel-backed VMFS as principal storage for workload domains, making it valid as the primary datastore type for the tier-1 business application cluster. Fibre Channel provides low-latency block storage, resilient pathing, SAN zoning, LUN masking, and mature enterprise performance characteristics. Because the existing FC arrays are partitioned by business unit, dedicated datastores preserve organizational separation and avoid mixing business-unit workloads on shared storage resources. The same dedicated FC-backed VMFS approach can also be used as supplemental storage after the workload domain exists, allowing extra capacity or specialized tiers while maintaining separation. Shared VMFS datastores do not satisfy the organizational separation requirement because they allow multiple business units to consume the same datastore boundary. vSAN is explicitly excluded, so the design must rely on supported non-vSAN storage. Automated VM placement can be supported by VMFS datastore clusters and Storage DRS where datastores are compatible and similarly managed. Reference topics: Fibre Channel Storage Model, VMFS Datastores, Principal Storage, Supplemental Storage, Datastore Clusters.



Unlock Premium 3V0-23.25 Exam Questions with Advanced Practice Test Features:
  • Select Question Types you want
  • Set your Desired Pass Percentage
  • Allocate Time (Hours : Minutes)
  • Create Multiple Practice tests with Limited Questions
  • Customer Support
Get Full Access Now

Save Cancel